The Building Thermal Comfort Research Laboratory located in MITEC is a laboratory where simulation studies on thermal energy technologies, one of the strategic areas of study of the company, are carried out. The focus of the laboratory is the test chamber. The test chamber consists of an inner space and four different outer spaces in which the environmental conditions are simulated. Regional climatic conditions can be achieved by setting the desired temperature, humidity and wind speed values ​​in the outer spaces that can be conditioned under control. These outer spaces are in four parts: north and west part, east and south part, under part and upper part of the room. In these four different ambient spaces, the temperature can be precisely controlled in the range of -15 to + 45 °C, relative humidity in the range of 10% to 90%, and wind speed in the range of 0 to 5 m/s. The heat transfer coefficient of the wall elements of the test chamber was selected to correspond to the U value of an average building. When determining this value, heat transfer coefficients have been selected considering the heat transfer coefficients of the heating zones in Turkey according to Standard TS 825.

Our team of engineers and basic scientists, each of whom is specialized in their fields, offers the following infrastructure and testing services to industrial organizations from different sectors as well as our researches within the company.

Equipment Available in the Building Thermal Comfort Research Laboratory

Device List

Device Features

Emko ESM-3710-N Digital temperature controller

  • Temperature sensör girişi: NTC, PTC, J veya K tipi TC, 2 telli PT100, 2 telli PT1000
  • Seçilebilir ısıtma veya soğutma fonksiyonu
  • Scale:
    • Fe-CuNi 0°C…800°C
    • NiCr-Ni 0°C…999°C
    • PT 100 -50°C…400°C / -19.9°C…99.9°C
    • NTC -50°C…100°C
    • PTC -50°C…150°C
  • Accuracy: ± % 1 of the full scale
  • Reading frequency: 3 readings per second
  • Communication protocol: RS-485, Prokey Programming module

Optris PI 160 Thermal camera

  • Temperature measurement range -20 to 100 °C
  • Reading frequency: 120 Hz
  • Optical resolution: 160×120 pixels
  • Detector: 25 μm x 25 μm uncooled FPA
  • Spectral range: 8 – 14 μm
  • Accuracy: ±2 ° or ±%2

Innova 1221 Thermal comfort datalogger

  • UA1276 comfort module
    • Temperature (MM0060): -20 to 100 °C (resolution 0,1°C)
    • Humidity (MM0037)
    • Air speed(MM0038): 0-10 m/s
  • UA1277 thermal stress module
    • Temperature (MM0034, MM0035, MM0060): -40 to 150 °C (resolution 0,1°C)
    • WBGT (MM0030): -40 to 150 °C (resolution 0,1°C)
    • Radiation (MM0036): ±50°C
  • UA1278 dry heat loss module
    • Dry heat loss (MM0057): 0-205 W/m2 (resolution 0,1 W/m2)
    • Operative (MM0057): -20 to 50 °C (resolution 0,1°C)
  • UA1346 dry heat loss module
    • Analogue input: 0-10 V (Current 0-20mA)
  • Data logging capacity: 10240 values (instantaneous, max, min, average, standard deviation)

CEM DT-618 Thermal anemometer

  • Air speedmeasurement range: 0,4-30 m/s (Accuracy: ±%2 , ±0,20 m/s)
  • Temperature measurement range -10 to 60 °C (Accuracy: ±%2 °C)

PCE 009 Hot wire anemometer

  • Air speed measurement range: 0,2-20 m/s (Accuracy: ±%5)
  • Air flow measurement range: 0-36000 m3/minute (Accuracy: 0,001-1)
  • Temperature measurement range 0 to 50 °C (Accuracy: ±%0,1 °C)

PCE-PFM 2 Pitot tube anemometer

  • Air speed measurement range: 1-80 m/s (Accuracy: ±%2,5)
  • Air flow measurement range: 0-100 m3/minute (Accuracy: 0,001-100)
  • Temperature measurement range 0 to 50 °C (Accuracy: ±%1 °C)

Optris CT fast LT Infrared thermometer

  • Temperature measurement range -50 to 600 °C (Accuracy: ±%1 , ±1°C)
  • Spectral response: 8-14 μm
  • Area of use: Non-metallic surfaces
  • Optical resolution: 2:1
  • Response time: 150 ms

SCHILTKNECHT Scantemp 486 Infrared thermometer

  • Temperature measurement range: -60 to 550 °C (Accuracy: ±%2 , ±2°C)
  • Spectral response: 6-14 μm
  • Laser aiming and illumination
  • Optical resolution: 12:1
  • Display resolution: 0,1 °C
  • Areas of use:
    • Moving parts
    • Untouchable parts (new painted) – Food and caustic substances
    • Live parts (electrical components,transformers)

Neslab RTE300 Cooler-Heater circulator

  • Temperature range: -25 to 150 °C
  • Temperature stability: ±0,01°C
  • Cooling capacity: 20°C’de 500 W
  • Heating capacity: 2000 W

Kimo Instruments TH300 Temperature and Relative Humidity Transmitter

  • Humidity measurement range: %0-%100 RH (Accuracy: ±%1,5 RH)
  • Response time: <10 sn
  • Resolution: %0,1 RH
  • Humidity sensor type : Capacitive
  • Temperature measurement range: -40 to 180 °C (Accuracy: ±%0,3 , ±0,25°C)
  • Resolution: 0,1 °C
  • Temperature sensor type : PT100 stainless steel probe

E+E Elektronik EE10-FT6D04/T31 Temperature and Relative Humidity Transmitter

  • Humidity measurement range: %0-%100 RH (Accuracy: ±%2 RH)
  • Humidity sensor type : HC103
  • Temperature measurement range: 0 to 50 °C (Accuracy: ±0,25°C)
  • Analogue output: 0-10 V 4-20mA

Trotec TTR 250 Absorbtion dehumidifier

  • Dehumidifying performance: 1,1 kg/h
  • Dry air usage zone : 130-300 m3/h
  • Nominal Air volume/pressure: 250 m3/h / 100 Pa
  • Regeneration Air Volume: 50m3/h / 100 Pa
  • Suction temperature: -15..+35 °C

The list of tests performed on request in the building thermal comfort research laboratory infrastructure is given below.

Tests Performed In The Building Thermal Comfort Research Laboratory

Name of test

Related standard

Water based surface embedded heating and cooling systems. Floor heating: Prove methods for the determination of the thermal output using calculation and test methods

BS EN 1264-2:2008+A1:2012

Water based surface embedded heating and cooling systems – Part 5: Heating and cooling surfaces embedded in floors, ceilings and walls – Determination of the thermal output

TS EN 1264-5:2010

Free hanging heating and cooling surfaces for water with a temperature below 120°C. Pre-fabricated ceiling mounted radiant panels for space heating. Test method for thermal output

BS EN 14037-2 :2016

Free hanging heating and cooling surfaces for water with a temperature below 120°C. Prefabricated ceiling mounted radiant panels for space heating. Rating method and evaluation of radiant thermal output

BS EN 14037-3 :2016

Radiators and convectors. Test methods and rating

BS EN 442-2 :2015

Moderate thermal environments-Determination of the PMV and PPD indices and specification of the conditions for thermal comfort

TS EN ISO 7730 :2016

Method of Testing for Rating Ceiling Panels for Sensible Heating and Cooling

ANSI/ASHRAE 138-2013 (R2016)

Free hanging heating and cooling surfaces for water with a temperature below 120°C. Pre-fabricated ceiling mounted radiant panels. Test method for cooling capacity

BS EN 14037-4:2016

Free hanging heating and cooling surfaces for water with a temperature below 120°C. Open or closed heated ceiling surfaces. Test method for thermal output

BS EN 14037-5:2016

Ventilation for buildings. Chilled ceilings. Testing and rating

BS EN 14240:2004

Thermal Environmental Conditions for Human Occupancy

ANSI/ASHRAE 55-2017